Addressable Fire Alarm Control Panel

JBE-P2L1

has EN 54 Certificate, a 7” LCD display with 800 X 480 resolution, 6 auxiliary function keys, 4 control keys, keypad with 12 numeric keys, 11 LED indicators and 30 zones LED making it a highly intuitive fire alarm user interface allowing the user to totally setup the system without the need of any external tool

Addressable Smoke Detector

JBE-2111

is an addressable optical smoke detector designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol. This detector responds to various types of smoke from the early stages and incorporates a pollution compensation feature which extends its service life, while preventing false alarms resulting from dust accumulation that has European standards EN 54-7. 

Addressable Heat Detector

JBE-2106

is an addressable heat detector designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol. This heat detector sends fire alarm signals to the fire panel when the air temperature (or its rate of rise) reaches the alarm thresholds defined in the European standards EN 54-5. The detector features three (3) sensitivity profiles: A2R, A2 and A2S

Addressable Smoke and Heat Detector

JBE-2115

is an addressable combined optical smoke and heat detector designed that has EN 54-7 and EN 54-5 certificate to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol. It sends fire alarm signals to the fire panel when the preselected levels of heat or smoke are detected. The detector features six (6) profiles, which combine different levels of heat and smoke.

Addressable Manual Call Point

JBE-2100

JBE-2100 is an addressable manual call point (MCP) designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol and has EN 54-11 certificate. After activation, the MCP will remain in alarm until it is reset with the supplied reset key. There is no glass break element in this device, so the reset operation is conveniently done without the need to replace any element.

Addressable Sounder – Beacon

JBE-2235

JBE-2235 is an addressable EN 54-3 sounder designed to operate in a loop of intelligent fire detection and alarm devices with the JBE loop protocol. The sounder device receives activation commands from the JBE fire panel and generates its sound output accordingly

Addressable Sounder

JBE-2135

JBE-2135 is an addressable EN 54-3 sounder designed to operate in a loop of intelligent fire detection and alarm devices with the JBE loop protocol. The sounder needs to be connected to both the JBE communication bus and to the 24 V power bus.

Addressable Sounder – Beacon (VID)

JBE-2145

JBE-2145 is an addressable EN 54-3 sounder with visual indicator (VID) designed to operate in a loop of intelligent fire detection and alarm devices with the JBE loop protocol. The visual indicator activates at the same time as the sounder. This visual indication is ancillary and not intended to meet the requirements of EN 54-23 beacons.

Addressable Input Module

JBE-2120

JBE-2120 is an addressable input module designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol and has EN 54-18 certificate. This input is electrically isolated from the loop and can be used for monitoring the state of one normally open dry-contact switch.

Addressable Output Module w/ Feedback Input

JBE-2125

JBE-2125 is an addressable output module with one feedback input designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol. Each module provides one output to the fire detection system and one feedback input that been certified with EN 54-18.

Addressable Conventional Zone Module

JBE-2200

JBE-2200 is an addressable conventional zone module designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol and has EN 54-18 certificate. The module is loop-powered or loop-powered plus 24 V DC power bus.

Isolator Module

JBE-2150

JBE-2150 is an isolator module designed to operate on a loop of intelligent fire detection and alarm devices with the JBE loop protocol and has EN 54-17 certificate. The isolator modules don’t use address from the loop and it’s not required to program an address.

Conventional Optical Smoke Detector

JBE-2112

JBE-2112 is a conventional optical smoke detector designed to operate on a zone line of intelligent fire detection and alarm devices. This smoke detector sends fire alarm signals to the fire panel when the detected smoke value reaches the preset alarm thresholds defined in the European norm EN 54-7.

Conventional Heat Detector

JBE-2107

JBE-2107 is a conventional heat detector designed to operate on a zone line of conventional intelligent fire detection and alarm devices. This heat detector sends fire alarm signals to the fire panel when the air temperature (or its rate of rise) reaches the alarm thresholds defined in the European norm EN 54-5 that have three (3) sensitivity profiles: A2R, A2 and A2S.

Conventional Manual Call Point

JBE-2101

JBE-2101 is a conventional manual call point (MCP) designed to be compatible with a wide range of conventional fire panels and input modules and has EN 54-11 certificate. This MCP sets an installer-selectable resistive load to the fire loop when its resettable element is pressed.

Addressable Fire Alarm Control Panel

NFS-320E

The NFS-320’s modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. Wireless fire protection can be added with the SWIFT wireless gateway and devices.

Addressable Fire Alarm System

NFS2-640E

The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement.

Addressable Fire Alarm Control Panel

NFS2-3030E

The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. The NFS2- 3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelligent addressable devices.

Remote Fire Annunciator

FDU-80

The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote fire annunciator for use with NOTIFIER FireWarden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the appearance of a control panel and displays complete system point status information.

Liquid Crystal Display

LCD-160

The LCD-160 is a 640-character Liquid Crystal Display (LCD) annunciator and remote control for the NOTIFIER NFS-3030/ NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030’s 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and can display other panel information.

Control Module

FCM-1

The FCM-1(A) Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis.

Zone Module

FZM-1

The FZM-1 Interface Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the builtin rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors.

Relay Module

FRM-1

The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis.

Monitor Module

FMM-101

The FMM-101 monitor module can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting.

Fault Isolator Module

ISO-X

The Notifier ISO-X(A) Fault Isolator Module is used with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs) to protect the system against wire-to-wire short circuits on the SLC loops.

Photoelectric Smoke Detectors

FSP-851

Notifier FSP-851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. The FSP-851(A) photoelectric detector’s unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources.

Conventional Smoke Detectors

SD-651

The Notifier SD-651 Plug-in Smoke Detectors offer superb performance and reliability in a profile which is just 2” (5.1 cm) deep. Model SD-651 (photoelectric sensor) can be used with a variety of different adapter bases in several wiring configurations and voltages. 

Addressable Thermal (Heat) Detectors

FST-851

Notifier FST-851(A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conventional detectors. FST-851(A) Series thermal detectors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed-temperature (FST-851/A) and rate-ofrise thermal detection (FST-851R/A) in a low-profile package. 

Conventional Fixed/ROR Heat Detector

5601p

The 5600 Series offers a full line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are offered, each available for low- and high-temperature ratings with either fixedtemperature or combination fixed-temperature/rate-of-rise (ROR) activation.

Conventional Callpoint

M400K/T

The M400K is designed to provide a manual interface for causing an alarm on the fire alarm system. The two wire circuit design allows remote communication with the monitoring control panel while also providing a localized LED.

Horns, Strobes & Horn Strobes

SYS-ST / SYS-HS

The System Sensor line of notification devices offers the most flexible and easy-to-use line of horns, strobes, and horn strobes in the industry. With red housing, universal fire symbol and a ceiling mount accessory available these devices can meet virtually any application.

Alarm Bell

SSM24-6

System Sensor’s SSM Series alarm bells are low-current, high-decibel notification appliances for use in fire and burglary systems or other signaling applications. They come pre-wired to reduce installation time, and also incorporate a polarized electrical design for use with supervision circuitry.